RL78/G1A 
 
CHAPTER  6   TIMER  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
275  
Jul 04, 2013 
Figure 6-69.  Operation Procedure of One-Shot Pulse Output Function (2/2) 
 
 Software 
Operation 
Hardware 
Status 
Sets the TOEmp bit (slave) to 1 (only when operation is 
resumed).  
The TSmn (master) and TSmp (slave) bits of timer 
channel start register m (TSm) are set to 1 at the same 
time. 
The TSmn and TSmp bits automatically return to 0 
because they are trigger bits. 
 
 
 
 
The TEmn and TEmp bits are set to 1 and the master 
channel enters the start trigger detection (the valid edge of 
the TImn pin input is detected or the TSmn bit of the 
master channel is set to 1) wait status. 
 Counter stops operating. 
Operation 
start 
Count operation of the master channel is started by start 
trigger detection of the master channel. 
• Detects the TImn pin input valid edge. 
• Sets the TSmn bit of the master channel to 1 by 
software
Note
Note  Do not set the TSmn bit of the slave channel to 1. 
Master channel starts counting. 
During 
operation 
Set values of only the CISmn1 and CISmn0 bits of the 
TMRmn register can be changed. 
Set values of the TMRmp, TDRmn, TDRmp registers, 
TOMmn, TOMmp, TOLmn, and TOLmp bits cannot be 
changed. 
The TCRmn and TCRmp registers can always be read. 
The TSRmn and TSRmp registers are not used. 
Set values of the TOm and TOEm registers by slave 
channel can be changed. 
Master channel loads the value of the TDRmn register to 
timer count register mn (TCRmn) by the start trigger 
detection (the valid edge of the TImn pin input  is detected 
or the TSmn bit of the master channel is set to 1), and the 
counter starts counting down.  When the count value 
reaches TCRmn = 0000H, the INTTMmn output is 
generated, and the counter stops until the next start trigger 
detection. 
The slave channel, triggered by INTTMmn of the master 
channel, loads the value of the TDRmp register to the 
TCRmp register, and the counter starts counting down.  
The output level of TOmp becomes active one count clock 
after generation of INTTMmn from the master channel.  It 
becomes inactive when TCRmp = 0000H, and the 
counting operation is stopped. 
After that, the above operation is repeated. 
The TTmn (master) and TTmp (slave) bits are set to 1 at 
the same time. 
The TTmn and TTmp bits automatically return to 0 
because they are trigger bits. 
 
TEmn, TEmp = 0, and count operation stops. 
The TCRmn and TCRmp registers hold count value and 
stop. 
The TOmp output is not initialized but holds current 
status. 
Operation 
stop 
The TOEmp bit of slave channel is cleared to 0 and 
value is set to the TOmp bit. 
 
The TOmp pin outputs the TOmp set level. 
To hold the TOmp pin output level  
Clears the TOmp bit to 0 after the value to  
be held is set to the port register. 
When holding the TOmp pin output level is not 
necessary 
  Setting not required. 
 
 
The TOmp pin output level is held by port function. 
 
 
 
TAU 
stop 
The TAUmEN bit of the PER0 register is cleared to 0.
 
 Power-off 
status 
All circuits are initialized and SFR of each channel is 
also initialized. 
(The TOmp bit is cleared to 0 and the TOmp pin is set to 
port mode.) 
Remark  m: Unit number (m = 0), n: Channel number (n = 0, 2, 4, 6) 
 
p: Slave channel number (n < p 
≤ 7) 
 
However, timer output pin (TOmp) : p = 1, 3 to 7 
 
Oper
ation is 
re
su
med. 
<R> 