CHAPTER  7   REAL-TIME  CLOCK 
7.4.5  1 Hz output of real-time clock 
 
Figure 7-24.  1 Hz Output Setting Procedure 
 
Start
RTCE = 0
Stops counter operation.
RCLOE1 = 1
Enables output of the RTC1HZ pin (1 Hz).
RTCE = 1
Starts counter operation.
Output start from RTC1HZ pin
Setting port
Sets P30 = 0 and PM30 = 0
<R> 
 
 
Cautions  1.  First set the RTCEN bit to 1, while oscillation of the count clock (f
SUB
) is stable. 
 
2.  1 Hz output function of real-time clock is not available in the 25- and 32-pin products. 
<R> 
 
 