Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
CHAPTER  9   CLOCK  OUTPUT/BUZZER  OUTPUT  CONTROLLER 
Figure 9-2.  Format of Clock Output Select Register n (CKSn)  
 
Address:  FFFA5H (CKS0), FFFA6H (CKS1)     After reset:  00H     R/W 
Symbol 
<7> 
6 5 4 3 2 1 0 
CKSn 
PCLOEn 
0 0 0 
CSELn 
CCSn2 
CCSn1 
CCSn0 
 
 
PCLOEn 
PCLBUZn pin output enable/disable specification 
 
Output disable (default) 
 1 
Output 
enable 
 
PCLBUZn pin output clock selection 
 
CSELn CCSn2 CCSn1 CCSn0
 
f
MAIN
 =  
5 MHz 
f
MAIN
 =  
10 MHz 
f
MAIN
 =  
20 MHz 
f
MAIN
 =  
32 MHz 
 
0 0 0 0 
f
MAIN 
5 MHz 
Setting 
prohibited
Note
Setting 
prohibited
Note
 
Setting 
prohibited
Note
 
0 0 0 1 
f
MAIN
/2 
2.5 MHz 
5 MHz 
Setting 
prohibited
Note
 
Setting 
prohibited
Note
 
0 0 1 0 
f
MAIN
/2
2
1.25 MHz 
2.5 MHz 
5 MHz 
8 MHz
 Note
 
 
0 0 1 1 
f
MAIN
/2
3
625 kHz 
1.25 MHz 
2.5 MHz 
4 MHz 
 
0 1 0 0 
f
MAIN
/2
4
312.5 kHz 
625 kHz 
1.25 MHz 
2 MHz 
 
0 1 0 1 
f
MAIN
/2
11
2.44 kHz 
4.88 kHz 
9.76 kHz 
15.63 kHz
 
0 1 1 0 
f
MAIN
/2
12
1.22 kHz 
2.44 kHz 
4.88 kHz 
7.81 kHz 
 
0 1 1 1 
f
MAIN
/2
13
610 Hz 
1.22 kHz 
2.44 kHz 
3.91 kHz 
 
1 0 0 0 
f
SUB
 32.768 
kHz 
 
1 0 0 1 
f
SUB
/2 16.384 
kHz 
 
1 0 1 0 
f
SUB
/2
2
 8.192 
kHz 
 
1 0 1 1 
f
SUB
/2
3
 4.096 
kHz 
 
1 1 0 0 
f
SUB
/2
4
 2.048 
kHz 
 
1 1 0 1 
f
SUB
/2
5
 1.024 
kHz 
 
1 1 1 0 
f
SUB
/2
6
 512 
Hz 
 
1 1 1 1 
f
SUB
/2
7
 256 
Hz 
 
Note  Use the output clock within a range of 8 MHz.  Furthermore, when using the output clock at 2.7 V 
≤ V
DD
 
< 4.0 
V, can be use it within 8 MHz only.  See 29.4 or 30.4  AC Characteristics for details. 
 
Cautions  1.  Change the output clock after disabling clock output (PCLOEn = 0). 
 
2.  To shift to STOP mode when the main system clock is selected (CSELn = 0), set PCLOEn = 0 
before executing the STOP instruction.  When the subsystem clock is selected (CSELn = 1), 
PCLOEn = 1 can be set because the clock can be output while the RTCLPC bit of the subsystem 
clock supply mode control register (OSMC) is set to 0 and moreover while STOP mode is set. 
<R> 
 
3.  It is not possible to output the subsystem clock (f
SUB
) from the PCLBUZn pin while the RTCLPC 
bit of the subsystem clock supply mode control register (OSMC), which controls the supply of 
the subsystem clock, is set to 1 and moreover while HALT mode is set with the subsystem clock 
(f
SUB
) selected as CPU clock. 
<R> 
 
Remarks 1. n = 0, 1 
 2.  f
MAIN
Main system clock frequency 
 
 
f
SUB
Subsystem clock frequency 
R01UH0305EJ0200  Rev.2.00 
 
 
330  