Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  11   A/D  CONVERTER 
R01UH0305EJ0200  Rev.2.00 
 
 
351  
Jul 04, 2013 
Cautions 1.  The A/D conversion time must also be within the relevant range of conversion times (t
CONV
described in 29.6.1 or 30.6.1  A/D converter characteristics. 
 
2.  When rewriting the FR2 to FR0, LV1, and LV0 bits to other than the same data, while in the 
conversion stopped (ADCS = 0, ADCE = 0). 
 
3.  The above conversion time does not include clock frequency errors.  Select conversion time, taking 
clock frequency errors into consideration. 
 
4.  When software trigger mode/hardware trigger no-wait mode, specify the conversion time so that the 
following conditions are satisfied: 
  f
AD
 is used within a range of 1 to 16 MHz. 
 When using ANI16 to ANI30, the A/D converter is used in the following range of AV
DD
, in 
accordance with the settings of the LV1 and LV0 bits: 
  When LV1 = 0, LV0 = 0:  Setting prohibit 
  When LV1 = 0, LV0 = 1:  2.4 V 
 AV
DD
 
 3.6 V 
  When LV1 = 1, LV0 = 0:  1.8 V 
 AV
DD
 
 3.6 V 
  When LV1 = 1, LV0 = 1:  1.6 V 
 AV
DD
 
 3.6 V 
  Condition when temperature sensor or internal reference voltage (ADISS bit of ADS register = 1) 
is set for the analog input channel: 
  When LV1 = 0, LV0 = 0: 
Setting prohibit 
  When other than LV1 = 0, LV0 = 0:  2.4 V 
 AV
DD
 
 3.6 V 
 
Remark  f
CLK
:  CPU/peripheral hardware clock frequency