Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  12   SERIAL  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
440  
Jul 04, 2013 
(2) Operation procedure 
 
Figure 12-25.  Initial Setting Procedure for Master Transmission 
 
Set an operation mode, etc. 
Starting initial setting 
Setting the PER0 register
Setting the SPSm register
Setting the SMRmn register
Setting the SCRmn register
Setting the SDRmn register
Setting the SOm register
Setting of the SOEm register
Setting port 
Writing to the SSm register
Completing initial setting
Release the serial array unit from the 
reset status and start clock supply.
 
Set the operation clock. 
Set a communication format. 
Set the initial output level of the serial 
clock (CKOmn) and serial data (SOmn). 
Set the SOEmn bit to 1 and enable data 
output of the target channel. 
Setting a port register and a port mode 
register (Enable data output and clock 
output of the target channel by) 
Setting of SAU is completed.   
Write transmit data to the SIOp register 
(bits 7 to 0 of the SDRmn register) and 
start communication. 
Set the SSmn bit of the target channel to 1 
(SEmn bit = 1: to enable operation). 
Set a transfer baud rate (setting the 
transfer clock by dividing the operation 
clock (f
MCK
)). 
 
 
Remark  m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), p: CSI number (p = 00, 01, 10, 11, 20, 21), 
mn = 00 to 03, 10, 11