Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  12   SERIAL  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
442  
Jul 04, 2013 
Figure 12-27.  Procedure for Resuming Master Transmission 
 
Starting setting for resumption
Port manipulation 
Changing setting of the SPSm register
Changing setting of the SMRmn register
Writing to the SSm register
Completing resumption 
Disable data output and clock output of 
the target channel by setting a port 
register and a port mode register. 
Re-set the register to change the operation 
clock setting. 
Re-set the register to change the transfer 
baud rate setting (setting the transfer 
clock by dividing the operation clock 
(f
MCK
)). 
Re-set the register to change serial mode 
register mn (SMRmn) setting. 
Set the initial output level of the serial 
clock (CKOmn) and serial data (SOmn). 
Enable data output and clock output of 
the target channel by setting a port 
register and a port mode register. 
Set the SSmn bit of the target channel to 1 
(SEmn = 1: to enable operation). 
Setting is completed
Sets transmit data to the SIOp register (bits 
7 to 0 of the SDRmn register) and start 
communication.
 
(Essential) 
(Selective) 
(Selective) 
(Selective) 
(Selective) 
(Essential) 
(Essential) 
Re-set the register to change serial 
communication operation setting register 
mn (SCRmn) setting. 
(Selective) 
Changing setting of the SCRmn register
Set the SOEmn bit to 1 and enable output 
from the target channel. 
(Selective) 
Changing setting of the SOEm register
Set the SOEmn bit to 0 to stop output 
from the target channel. 
(Selective) 
Changing setting of the SOEm register
Master ready?
(Essential) 
Yes 
No 
Wait until stop the communication target 
(slave) or communication operation 
completed 
Changing setting of the SDRmn register
Port manipulation 
Changing setting of the SOm register
 
 
Remarks 1.  If PER0 is rewritten while stopping the master transmission and the clock supply is stopped, wait 
until the transmission target (slave) stops or transmission finishes, and then perform initialization 
instead of restarting the transmission. 
 2. 
m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), p: CSI number (p = 00, 01, 10, 11, 20, 
21), mn = 00 to 03, 10, 11