Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  12   SERIAL  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
470  
Jul 04, 2013 
(2) Operation procedure 
 
Figure 12-49.  Initial Setting Procedure for Slave Transmission 
 
Set an operation mode, etc. 
Starting initial setting 
Setting the PER0 register
Setting the SPSm register
Setting the SMRmn register
Setting the SCRmn register
Setting the SDRmn register
Setting the SOm register
Changing setting of the SOEm register
Setting port 
Writing to the SSm register
Completing initial setting
Release the serial array unit from the 
reset status and start clock supply.
Set the operation clock. 
Set a communication format. 
Set the initial output level of the serial 
data (SOmn). 
Set the SOEmn bit to 1 and enable data 
output of the target channel. 
Enable data output of the target channel 
by setting a port register and a port mode 
register. 
Initial setting is completed. 
Set transmit data to the SIOp register (bits 
7 to 0 of the SDRmn register) and wait for 
a clock from the master. 
Set the SSmn bit of the target channel to 1 
(SEmn bit = 1: to enable operation). 
Set bits 15 to 9 to 0000000B for baud rate 
setting. 
 
 
Remark  m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), p: CSI number (p = 00, 01, 10, 11, 20, 21), 
mn = 00 to 03, 10, 11