Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  12   SERIAL  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
545  
Jul 04, 2013 
The channel supporting simplified I
2
C (IIC00, IIC01, IIC10, IIC11, IIC20, IIC21) is channels 0 to 3 of SAU0 and channel 
0 and 1 of SAU1. 
 
•  25-pin products 
Unit 
Channel 
Used as CSI 
Used as UART 
Used as Simplified I
2
0 CSI00 
IIC00 
− 
UART0 
− 
− 
− 
3 CSI11 
UART1 
IIC11 
 
•  32-pin products 
Unit 
Channel 
Used as CSI 
Used as UART 
Used as Simplified I
2
0 CSI00 
IIC00 
− 
UART0 
− 
− 
− 
3 CSI11 
UART1 
IIC11 
0 CSI20 
IIC20 
− 
UART2 (supporting LIN-bus)
− 
 
•  48-pin products 
Unit 
Channel 
Used as CSI 
Used as UART 
Used as Simplified I
2
0 CSI00 
IIC00 
1 CSI01 
UART0 
IIC01 
− 
− 
3 CSI11 
UART1 
IIC11 
0 CSI20 
IIC20 
1 CSI21 
UART2 (supporting LIN-bus)
IIC21 
 
•  64-pin products 
Unit 
Channel 
Used as CSI 
Used as UART 
Used as Simplified I
2
0 CSI00 
IIC00 
1 CSI01 
UART0 
IIC01 
2 CSI10 
IIC10 
3 CSI11 
UART1 
IIC11 
0 CSI20 
IIC20 
1 CSI21 
UART2 (supporting LIN-bus)
IIC21 
 
 