Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  12   SERIAL  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
549  
Jul 04, 2013 
Figure 12-103.  Example of Contents of Registers for Address Field Transmission of Simplified I
2
C (IIC00, IIC01, 
IIC10, IIC11, IIC20, IIC21) (2/2) 
 
(e)  Serial output enable register m (SOEm) 
 
15 
14 
13
12 
11 
10
9 8 7 6 5 4 3 2 1 0   
SOEm 
 
 
 
 
 
 
 
 
 
 
 
 
SOEm3
 
 
0/1
Note
 
SOEm2
 
 
0/1
Note
 
SOEm1 
0/1
 
SOEm0
0/1
 
 
 
 
 
 
 
 
SOEmn = 0 until the start condition is generated, and SOEmn = 
1 after generation.
 
 
 
(f)  Serial channel start register m (SSm) … Sets only the bits of the target channel is 1. 
 
15 
14 
13
12 
11 
10
9 8 7 6 5 4 3 2 1 0   
SSm 
 
 
 
 
 
 
 
 
 
 
 
 
SSm3
 
 
0/1
Note
 
SSm2
 
 
0/1
Note
 
SSm1 
0/1
 
SSm0
0/1
 
 
 
 
 
 
 
 
SSmn = 0 until the start condition is generated, and SSmn = 1 
after generation.
 
 
 
Note  Unit 0 only 
 
Remarks 1.  m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), r: IIC number (r = 00, 01, 10, 11, 20, 21), 
mn = 00 to 03, 10, 11 
 2. 
      : Setting disabled (set to the initial value)  
 
 
0/1: Set to 0 or 1 depending on the usage of the user