Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  12   SERIAL  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
554  
Jul 04, 2013 
(1) Register setting 
 
Figure 12-107.  Example of Contents of Registers for Data Transmission of Simplified I
2
C  
(IIC00, IIC01, IIC10, IIC11, IIC20, IIC21) (1/2) 
 
(a)  Serial mode register mn (SMRmn) … Do not manipulate this register during data  
  
transmission/reception. 
 
15 
14 
13
12 
11 
10
9 8 7 6 5 4 3 2 1 0   
SMRmn 
CKSmn 
0/1 
CCSmn 
 
 
0
 
 
0
 
 
0
 
 
0
 
STSmn
0
Note 1
 
0
 
SISmn0
0
Note 1
 
1
 
 
0
 
 
0
 
MDmn2 
1
 
MDmn1 
0
 
MDmn0
0
 
 
 
(b)  Serial communication operation setting register mn (SCRmn) … Do not manipulate the bits of this  
 
 
register, except the TXEmn and  
 
 
RXEmn bits, during data  
  
transmission/reception. 
 
15 
14 
13
12 
11 
10
9 8 7 6 5 4 3 2 1 0   
SCRmn 
TXEmn 
RXEmn 
DAPmn
CKPmn 
0
 
 
0
 
EOCmn
0
 
PTCmn1
0
 
PTCmn0
0
 
DIRmn
0
 
 
0
 
SLCmn1
0
Note 2
SLCmn0
1
 
 
0
 
 
1
 
DLSmn1 
1
Note 3
 
DLSmn0
1
 
 
 
(c)  Serial data register mn (SDRmn) (lower 8 bits: SIOr) …  During data transmission/reception, valid only 
 
lower 8-bits (SIOr) 
 
15 
14 
13
12 
11 
10
9 8 7 6 5 4 3 2 1 0   
SDRmn 
 
Baud rate setting
Note 4
 
 
0
 
 
Transmit data setting 
 
 
 
(d)  Serial output register m (SOm) …  Do not manipulate this register during data  
  
transmission/reception. 
 
15 
14 
13
12 
11 
10
9 8 7 6 5 4 3 2 1 0   
SOm 
 
 
 
 
0
 
CKOm3
 
Note 5
 
0/1 
Note 6
 
CKOm2
 
Note 5
 
0/1
Note  6
CKOm1
0/1
Note 6
CKOm0
0/1
Note 6
 
0
 
 
0
 
 
0
 
 
0
 
SOm3
 
Note 5
 
0/1 
Note  6
 
SOm2
 
Note 5
 
0/1 
Note  6
 
SOm1 
0/1 
Note 6
 
SOm0
0/1
Note  6
 
 
Notes 1.  Only provided for the SMR01, SMR03, and SMR11 registers. 
 
2.  Only provided for the SCR00, SCR02, and SCR10 registers. 
 
3.  Only provided for the SCR00 and SCR01 registers.  This bit is fixed to 1 for the other registers. 
 
4.  Because the setting is completed by address field transmission, setting is not required. 
 5.  Unit 0 only. 
 
6.  The value varies depending on the communication data during communication operation. 
 
Remarks 1.  m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), r: IIC number (r = 00, 01, 10, 11, 20, 21), 
mn = 00 to 03, 10, 11 
 2. 
     : Setting is fixed in the IIC mode,      : Setting disabled (set to the initial value)  
 
 
0/1: Set to 0 or 1 depending on the usage of the user 
SIOr 
<R> 