RL78/G1A 
 
CHAPTER  13   SERIAL  INTERFACE  IICA 
13.3.5  IICA control register 01 (IICCTL01) 
This register is used to set the operation mode of I
2
C and detect the statuses of the SCLA0 and SDAA0 pins. 
The IICCTL01 register can be set by a 1-bit or 8-bit memory manipulation instruction.  However, the CLD0 and DAD0 
bits are read-only. 
Set the IICCTL01 register, except the WUP0 bit, while operation of I
2
C is disabled (bit 7 (IICE0) of IICA control register 
00 (IICCTL00) is 0). 
Reset signal generation clears this register to 00H. 
 
Figure 13-9.  Format of IICA Control Register 01 (IICCTL01) (1/2) 
 
Address:  F0231H 
After reset:  00H 
R/W
Note 1
 
Symbol 
<7> 6 <5> 
<4> 
<3> 
<2> 1 <0> 
IICCTL01 WUP0 
CLD0 
DAD0  SMC0  DFC0 
PRS0 
 
WUP0 
Control of address match wakeup 
Stops operation of address match wakeup function in STOP mode. 
Enables operation of address match wakeup function in STOP mode. 
To shift to STOP mode when WUP0 = 1, execute the STOP instruction at least three clocks of f
MCK
 after setting 
(1) the WUP0 bit (see Figure 13-22  Flow When Setting WUP0 = 1). 
Clear (0) the WUP0 bit after the address has matched or an extension code has been received.  The 
subsequent communication can be entered by the clearing (0) WUP0 bit.  (The wait must be released and 
transmit data must be written after the WUP0 bit has been cleared (0).) 
The interrupt timing when the address has matched or when an extension code has been received, while WUP0 
= 1, is identical to the interrupt timing when WUP0 = 0.  (A delay of the difference of sampling by the clock will 
occur.)  Furthermore, when WUP0 = 1, a stop condition interrupt is not generated even if the SPIE0 bit is set to 
1. 
When WUP0 = 0 is set by a source other than an interrupt from serial interface IICA, operation as the master 
device cannot be performed until the subsequent start condition or stop condition is detected.  Do not output a 
start condition by setting (1) the STT0 bit, without waiting for the detection of the subsequent start condition or 
stop condition. 
Condition for clearing (WUP0 = 0) 
Condition for setting (WUP0 = 1) 
• Cleared by instruction (after address match or 
extension code reception) 
• Set by instruction (when the MSTS0, EXC0, and 
COI0 bits are “0”, and the STD0 bit also “0” 
(communication not entered))
Note 2
 
 
Notes 1.  Bits 4 and 5 are read-only. 
 
2.  The status of the IICA status register 0 (IICS0) must be checked and the WUP0 bit must be set 
during the period shown below. 
 
SCLA0
<1>
<2>
SDAA0
A6
A5
A4
A3
A2
A1
A0
The maximum time from reading IICS0 to setting 
WUP0 is the period from <1> to <2>.
Check the IICS0 operation status and set 
WUP0 during this period.
R/W
 
R01UH0305EJ0200  Rev.2.00 
 
 
583  
Jul 04, 2013