CHAPTER  18   STANDBY  FUNCTION 
18.3.3  SNOOZE mode 
 
(1)  SNOOZE mode setting and operating statuses 
The SNOOZE mode can only be specified for CSIp, UARTq, or the A/D converter.  Note that this mode can only be 
specified if the CPU clock is the high-speed on-chip oscillator clock. 
When using CSIp or UARTq in the SNOOZE mode, set the SWCm bit of the serial standby control register m (SSCm) 
to 1 immediately before switching to the STOP mode.  For details, see 12.3  Registers Controlling Serial Array Unit.  
When using the A/D converter in the SNOOZE mode, set the AWC bit of the A/D converter mode register 2 (ADM2) to 
1 immediately before switching to the STOP mode.  For details, see 11.3  Registers Used in A/D Converter
 
Remark  p = 00; q = 0; m = 0 
 
The following time is required for mode transition. 
Transition time from STOP mode to SNOOZE mode:   18 to 65 
μ
 
Remark   The time required to transition from STOP mode to SNOOZE mode depends on the temperature conditions 
and the STOP mode period. 
 
Transition time from SNOOZE mode to normal operation: 
•  When vectored interrupt servicing is carried out:  
HS (High-speed main) mode:   4.99 to 9.44 
μ
s + 7 clocks 
LS (Low-speed main) mode:  
1.10 to 5.08 
μ
s + 7 clocks 
LV (Low-voltage main) mode:   16.58 to 25.40 
μ
s + 7 clocks 
•  When vectored interrupt servicing is not carried out:  
HS (High-speed main) mode:   4.99 to 9.44 
μ
s + 1 clock 
LS (Low-speed main) mode:  
1.10 to 5.08 
μ
s + 1 clock 
LV (Low-voltage main) mode:   16.58 to 25.40 
μ
s + 1 clock 
 
The operating statuses in the SNOOZE mode are shown below. 
R01UH0305EJ0200  Rev.2.00 
 
 
737  
Jul 04, 2013