CHAPTER  22   SAFETY  FUNCTIONS 
22.3.7.1  Timer input select register 0 (TIS0) 
<R> 
The TIS0 register is used to select the timer input of channel 5 of the timer array unit 0 (TAU0). 
The TIS0 register can be set by an 8-bit memory manipulation instruction. 
Reset signal generation clears this register to 00H. 
 
Figure 22-14.  Format of Timer Input Select Register 0 (TIS0) 
 
Address: F0074H     After reset: 00H     R/W 
Symbol 
7 6 5 4 3 2 1 0 
TIS0 
0 0 0 0 0 
TIS02 
TIS01 
TIS00 
 
TIS02 TIS01 TIS00 
Selection 
of 
timer input used with channel 5 
0 0 0 
0 0 1 
0 1 0 
0 1 1 
Input signal of timer input pin (TI05) 
Low-speed on-chip oscillator clock (f
IL
1 0 1 
Subsystem 
clock 
(f
SUB
Other than above 
Setting prohibited 
 