Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
CHAPTER  29   ELECTRICAL  SPECIFICATIONS  (T
A
  =  
−40  to  +85°C) 
R01UH0305EJ0200  Rev.2.00 
 
 
859  
Jul 04, 2013 
29.3.2  Supply current characteristics 
 
(T
A
 = 
40 to +85°C, 1.6 V  EV
DD0
 
 V
DD
 
 3.6 V, V
SS
 = EV
SS0
 = 0 V) 
(1/3) 
Parameter Symbol 
Conditions 
MIN.  TYP.  MAX.
Unit
Basic 
operation
V
DD
 = 3.0 V
 
2.1 
 
mA
f
IH
 = 32 MHz
Note 3
 
Normal 
operation
V
DD
 = 3.0 V
 
4.6 
7.0 
mA
f
IH
 = 24 MHz
Note 3
 Normal 
operation
V
DD
 = 3.0 V
 
3.7 
5.5 
mA
 
HS (high-speed 
main) mode
Note 5
 
f
IH
 = 16 MHz
Note 3
 Normal 
operation
V
DD
 = 3.0 V
 
2.7 
4.0 
mA
 
V
DD
 = 3.0 V
 
1.2 
1.8 
LS (low-speed 
main) mode
Note 5
 
f
IH
 = 8 MHz
Note 3
 Normal 
operation
V
DD
 = 2.0 V
 
1.2 
1.8 
mA
 
V
DD
 = 3.0 V
 
1.2 
1.7 
LV (Low-voltage 
main) mode
Note 5
 
f
IH
 = 4 MHz
Note 3
 Normal 
operation
V
DD
 = 2.0 V
 
1.2 
1.7 
mA
 
Square 
wave input
 3.0 
4.6 
f
MX
 = 20 MHz
Note 2
V
DD
 = 3.0 V 
Normal 
operation
Resonator 
connection
 3.2 
4.8 
mA
 
Square 
wave input
 1.9 
2.7 
HS (high-speed 
main) mode
Note 5
 
f
MX
 = 10 MHz
Note 2
V
DD
 = 3.0 V 
Normal 
operation
Resonator 
connection
 1.9 
2.7 
mA
 
Square 
wave input
 1.1 
1.7 
f
MX
 = 8 MHz
Note 2
V
DD
 = 3.0 V 
Normal 
operation
Resonator 
connection
 1.1 
1.7 
mA
 
Square 
wave input
 1.1 
1.7 
LS (low-speed 
main) mode
Note 5
 
f
MX
 = 8 MHz
Note 2
,  
V
DD
 = 2.0 V 
Normal 
operation
Resonator 
connection
 1.1 
1.7 
mA
 
Square 
wave input
 4.1 
4.9 
f
SUB
 = 32.768 kHz
Note 4  
T
A
 = 
−40°C 
Normal 
operation
Resonator 
connection
 4.2 
5.0 
μA
Square 
wave input
 4.2 
4.9 
f
SUB
 = 32.768 kHz
Note 4
T
A
 = +25
°C 
Normal 
operation
Resonator 
connection
 4.3 
5.0 
μA
Square 
wave input
 4.3 
5.5 
f
SUB
 = 32.768 kHz
Note 4
T
A
 = +50
°C 
Normal 
operation
Resonator 
connection
 4.4 
5.6 
μA
Square 
wave input
 4.5 
6.3 
f
SUB
 = 32.768 kHz
Note 4
T
A
 = +70
°C 
Normal 
operation
Resonator 
connection
 4.6 
6.4 
μA
Square 
wave input
 4.8 
7.7 
Supply 
current
Note 1
 
I
DD1
 Operating 
mode 
Subsystem 
clock mode 
f
SUB
 = 32.768 kHz
Note 4
T
A
 = +85
°C 
Normal 
operation
Resonator 
connection
 4.9 
7.8 
μA
 