Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
CHAPTER  29   ELECTRICAL  SPECIFICATIONS  (T
A
  =  
−40  to  +85°C) 
R01UH0305EJ0200  Rev.2.00 
 
 
883  
Jul 04, 2013 
(8)  Communication at different potential (1.8V, 2.5 V) (CSI mode) (master mode, SCKp... internal clock output) (1/2) 
(T
A
 = 
40 to +85°C, 1.8 V  EV
DD0
 
 V
DD
 
 3.6 V, V
SS
 = EV
SS0
 = 0 V) 
HS
Note 1
 LS
Note 2
 LV
Note 3
 
Parameter Symbol 
Conditions 
MIN.
MAX.
MIN.
MAX. MIN. MAX.
Unit
2.7 V 
≤ EV
DD0
 
≤ 3.6 V,  
2.3 V 
≤ V
b
 
≤ 2.7 V, 
C
b
 = 30 pF, R
b
 = 2.7 k
Ω 
t
KCY1
 
≥ 4/f
CLK
500  1150
 1150  ns 
SCKp cycle time 
t
KCY1
 
1.8 V 
≤ EV
DD0
 < 3.3 V,  
1.6 V 
≤ V
b
 
≤ 2.0 V
Note 4
,  
C
b
 = 30 pF, R
b
 = 5.5 k
Ω 
t
KCY1
 
≥ 4/f
CLK
1150
 1150
 1150
 
   ns 
2.7 V 
≤ EV
DD0
 
≤ 3.6 V, 2.3 V ≤ V
b
 
≤ 2.7 V, 
C
b
 = 30 pF, R
b
 = 2.7 k
Ω 
t
KCY1
/2 
− 
170 
 
t
KCY1
/2 
− 
170 
 
t
KCY1
/2 
− 
170 
 ns 
SCKp high-level width  t
KH1
 
1.8 V 
≤ EV
DD0
 < 3.3 V, 1.6 V 
≤ V
b
 
≤ 2.0 V
Note 4
,
C
b
 = 30 pF, R
b
 = 5.5 k
Ω 
t
KCY1
/2 
− 
458 
 
t
KCY1
/2 
− 
458 
 
t
KCY1
/2 
− 
458 
 ns 
2.7 V 
≤ EV
DD0
 
≤ 3.6 V, 2.3 V ≤ V
b
 
≤ 2.7 V, 
C
b
 = 30 pF, R
b
 = 2.7 k
Ω 
t
KCY1
/2 
− 
18 
 
t
KCY1
/2 
− 
50 
 
t
KCY1
/2 
− 
50 
 ns 
SCKp low-level width  t
KL1
 
1.8 V 
≤ EV
DD0
 < 3.3 V, 1.6 V 
≤ V
b
 
≤ 2.0 V
Note 4
,
C
b
 = 30 pF, R
b
 = 5.5 k
Ω 
t
KCY1
/2 
− 
50 
 
t
KCY1
/2 
− 
50 
 
t
KCY1
/2 
− 
50 
 ns 
 
Notes 1.  HS is condition of HS (high-speed main) mode. 
 2.  LS is condition of LS (low-speed main) mode. 
 3.  LV is condition of LV (low-voltage main) mode. 
 4. 
Use it with EV
DD0 
≥ V
b
 
Caution  Select the TTL input buffer for the SIp pin and the N-ch open drain output (V
DD
 tolerance (When 25- to 
48-pin products)/EV
DD
 tolerance (When 64-pin products)) mode for the SOp pin and SCKp pin by using 
port input mode register g (PIMg) and port output mode register g (POMg).  For V
IH
 and V
IL
, see the DC 
characteristics with TTL input buffer selected. 
 
Remarks  1.  R
b
[
Ω]: Communication line (SCKp, SOp) pull-up resistance, C
b
[F]: Communication line (SCKp, SOp) load 
capacitance, V
b
[V]: Communication line voltage 
 2.  p: CSI number (p = 00, 10, 20), m: Unit number , n: Channel number (mn = 00, 02, 10),  
g: PIM and POM number (g = 0, 1) 
 3. 
CSI01, CSI11, and CSI21 cannot communicate at different potential.  Use other CSI for communication at 
different potential. 
 
<R>