Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
CHAPTER  29   ELECTRICAL  SPECIFICATIONS  (T
A
  =  
−40  to  +85°C) 
R01UH0305EJ0200  Rev.2.00 
 
 
885  
Jul 04, 2013 
CSI mode connection diagram (during communication at different potential) 
 
V
b
R
b
SCKp
SOp
SCK
SI
User device
SIp
SO
V
b
R
b
<Master>
RL78
microcontroller
 
 
Remarks  1.  R
b
[
Ω]: Communication line (SCKp, SOp) pull-up resistance, C
b
[F]: Communication line (SCKp, SOp) load 
capacitance, V
b
[V]: Communication line voltage 
 2.  p: CSI number (p = 00, 10, 20), m: Unit number , n: Channel number (mn = 00, 02, 10),  
g: PIM and POM number (g = 0, 1) 
 3. 
CSI01, CSI11, and CSI21 cannot communicate at different potential.  Use other CSI for communication at 
different potential.