Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
CHAPTER  30   ELECTRICAL  SPECIFICATIONS  (G:  INDUSTRIAL  APPLICATIONS  T
A
  =  
−40  to  +105°C) 
R01UH0305EJ0200  Rev.2.00 
 
 
920  
Jul 04, 2013 
Notes 1.  Current flowing to V
DD
 2.  When high-speed on-chip oscillator and high-speed system clock are stopped. 
 3. 
Current flowing only to the real-time clock (RTC) (excluding the operating current of the low-speed on-chip 
ocsillator and the XT1 oscillator).  The supply current of the RL78 microcontrollers is the sum of the values of 
either I
DD1
 or I
DD2
, and I
RTC
, when the real-time clock operates in operation mode or HALT mode.  When the 
low-speed on-chip oscillator is selected, I
FIL
 should be added.  I
DD2
 subsystem clock operation includes the 
operational current of the real-time clock. 
 4.  Current flowing only to the 12-bit interval timer (excluding the operating current of the low-speed on-chip 
ocsillator and the XT1 oscillator).  The supply current of the RL78 microcontrollers is the sum of the values of 
either I
DD1
 or I
DD2
, and I
IT
, when the 12-bit interval timer operates in operation mode or HALT mode.  When the 
low-speed on-chip oscillator is selected, I
FIL
 should be added.   
 5.  Current flowing only to the watchdog timer (including the operating current of the low-speed on-chip oscillator).  
The supply current of the RL78 microcontrollers is the sum of I
DD1
, I
DD2
, or I
DD3
 and I
WDT
 when the watchdog 
timer is in operation. 
 6. 
Current flowing only to the A/D converter.  The supply current of the RL78 microcontrollers is the sum of I
DD1
 or 
I
DD2
 and I
ADC
, I
AVREF
, I
ADREF
 when the A/D converter operates in an operation mode or the HALT mode.  
 
7.  Current flowing to the AV
DD
 8.  Current flowing from the reference voltage source of A/D converter. 
 9.  Operation current flowing to the internal reference voltage. 
 10. Current flowing to the AV
REFP
 11. Current flowing only to the LVD circuit.  The supply current of the RL78 microcontrollers is the sum of I
DD1
, I
DD2
 
or I
DD3
 and I
LVD 
when the LVD circuit is in operation. 
 12. 
Current flowing only during data flash rewrite. 
 13. 
Current flowing only during self programming. 
 14. For shift time to the SNOOZE mode, see 18.3.3  SNOOZE mode. 
 
Remarks 1.   f
IL
Low-speed on-chip oscillator clock frequency 
 
2.  f
SUB
:  Subsystem clock frequency (XT1 clock oscillation frequency) 
 
3.  f
CLK
:  CPU/peripheral hardware clock frequency 
 4.  Temperature condition of the TYP. value is T
A
 = 25
°C 
<R>