Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
APPENDIX  A   REVISION  HISTORY 
(3/5) 
Page Description 
Classification
CHAPTER  11   A/D CONVERTER 
p.361 Modification 
of 
Figure 11-1.  Block Diagram of A/D Converter (c) 
p.365 Modification 
of 
caution 1 in Figure 11-2. Format of Peripheral Enable Register 0 (PER0) 
(c) 
p.367 Modification 
of 
Table 11-1. Settings of ADCS and ADCE Bits (c) 
p.378 Modification 
of 
caution 1 in Figure 11-6. Format of A/D Converter Mode Register 1 (ADM1) 
(c) 
p.379, 380 
Modification of caution in Figure 11-7. Format of A/D Converter Mode Register 2 (ADM2) 
(c) 
p.385 
Modification of caution 5 in Figure 11-11. Format of Analog Input Channel Specification Register 
(ADS) 
(c) 
CHAPTER  12   SERIAL ARRAY UNIT 
p.424 Modification 
of 
note 1 in 12.1.1 3-wire serial I/O (CSI00, CSI01, CSI10, CSI11, CSI20, CSI21) (c) 
p.449 
Modification of 12.3.14 Serial standby control register 0 (SSC0), and addition of Table 12-2. 
Interrupt Using the UART Reception with SNOOZE Mode 
(c) 
p.451 
Modification of description in 12.3.16 Noise filter enable register 0 (NFEN0) 
(c) 
p.520 
Modification of figure and addition of note 2 to Figure 12-72. Timing Chart of SNOOZE Mode 
Operation (once startup) (Type 1: DAPmn = 0, CKPmn = 0) 
(c) 
p.522 
Modification of figure and addition of note 2 to Figure 12-74. Timing Chart of SNOOZE Mode 
Operation (continuous startup) (Type 1: DAPmn = 0, CKPmn = 0) 
(c) 
p.547 
Modification of description and caution 2 and addition of cautions 3, 4 to 12.6.3 SNOOZE mode 
function 
(c) 
p.548 Addition 
of Table 12-3. UART Reception Baud Rate Setting in the SNOOZE mode 
(c) 
p.549 
Addition of description in 12.6.3 (1) SNOOZE mode operation (EOCm1 = 0, SSECm = 0/1) 
(c) 
p.550 
Addition of description in 12.6.3  (2) SNOOZE mode operation (EOCm1 = 1, SSECm = 0: error 
interrupt (INTSRE0) generation enable) 
(c) 
p.551 
Modification of Figure 12-93. Flowchart of SNOOZE Mode Operation (EOCm1 = 0, SSECm = 0/1 
or EOCm1 = 1, SSECm = 0) 
(c) 
p.552 
Modification of 12.6.3 (3) SNOOZE mode operation (EOCm1 = 1, SSECm = 1: error interrupt 
(INTSRE0) generation stop) 
(c) 
p.553, 554 
Modification of Figure 12-95. Flowchart of SNOOZE Mode Operation (EOCm1 = 1, SSECm = 1) 
(c) 
p.557 Modification 
of 
12.6.4 (2) Baud rate error during transmission 
(c) 
CHAPTER  14   MULTIPLIER AND DIVIDER/MULTIPLY-ACCUMULATOR 
p.685 
Modification of description in 14.4.1 Multiplication (unsigned) operation 
(c) 
p.686 
Modification of description in 14.4.2 Multiplication (signed) operation 
(c) 
p.687 
Modification of description in 14.4.3 Multiply-accumulation (unsigned) operation 
(c) 
p.689 
Modification of description in 14.4.4 Multiply-accumulation (signed) operation 
(c) 
p.690 
Modification of Figure 14-9. Timing Diagram of Multiply-Accumulation (signed) Operation  
(2 × 3 + (
4) = 2  32767 × (1) + (2147483647) = 2147450882 (overflow occurs.)) 
(c) 
p.691 
Modification of description in 14.4.5 Division operation 
(c) 
CHAPTER  16   INTERRUPT  FUNCTION 
p.715 Addition 
of Note 5 to Table 16-1. Interrupt Source List 
(a) 
Remark  “Classification” in the above table classifies revisions as follows. 
 
(a): Error correction, (b): Addition/change of specifications, (c): Addition/change of description or note,  
(d): Addition/change of package, part number, or management division, (e): Addition/change of related 
documents 
R01UH0305EJ0200  Rev.2.00 
 
 
971  