NEC NDA-30130 User Manual

Page of 16
Page 2
NDA-30130  Revision 1
INSTALLATION & SET-UP
Voicemail Disconnect Installation & Operation Manual
Voicemail Disconnect Set-Up
Application 
Configuration
Voicemail Disconnect is supported internally by the APM, and must be configured 
in the APM environment. The Software Installation procedure configures the 
application using default values and creates the databases needed. 
Database Support
Voicemail Disconnect requires two APM databases: the Phone line database and 
the Tenant Number Database. Empty databases are created during initial software 
installation, but specific records must be added before Voicemail Disconnect is 
enabled.
Note:
If Second Party Alert Ver1.7 or higher has been previously installed, then these 
databases have already been created.
Phone Line Database
The Phone Line database consists of a Master Database file component and an 
Application Database file component.
Master Database File filename -  ’phone_m’.
The phone_m master database structure and example entries are shown in the table 
below.
Field Definitions
-  Phone Line 1 field is the primary extension number (five-digits max.). The 
number that is displayed with the caller’s name when this phone is used to 
place the call. 
-  Phone Line 2 - 6 fields are the secondary, or virtual, lines that are associated 
with the primary extension that was entered in the first field. These virtual 
lines must be assigned to this primary line through the NEAX Maintenance 
Administration Terminal (see NEAX2400 System Manuals). 
Field Name
Type
Size
Min. 
Value
Max. 
Value
Example
Entry
Phone Line 1
N
5
0
99999
4290
Phone Line 2
N
5
0
99999
4291
Phone Line 3
N
5
0
99999
4292
Phone Line 4
N
5
0
99999
4293
Phone Line 5
N
5
0
99999
4294
Phone Line 6
N
5
0
99999
4295