Brocade FCX-2XG Data Sheet

Page of 8
DATA SHEET
www.brocade.com
© 2010 Brocade Communications Systems, Inc. All Rights Reserved. 09/10 GA-DS-1352-04
Brocade, the B-wing symbol, BigIron, DCFM, DCX, Fabric OS, FastIron, IronView, NetIron, SAN Health, ServerIron,
TurboIron, and Wingspan are registered trademarks, and Brocade Assurance, Brocade NET Health, Brocade One,
Extraordinary Networks, MyBrocade, and VCS are trademarks of Brocade Communications Systems, Inc., in the United
States and/or in other countries. Other brands, products, or service names mentioned are or may be trademarks or
service marks of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied,
concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the
right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This
informational document describes features that may not be currently available. Contact a Brocade sales office for
information on feature and product availability. Export of technical data contained in this document may require an
export license from the United States government.
Corporate Headquarters 
San Jose, CA USA
T: +1-408-333-8000
info@brocade.com
European Headquarters 
Geneva, Switzerland
T: +41-22-799-56-40
emea-info@brocade.com
Asia Pacific Headquarters 
Singapore
T: +65-6538-4700
apac-info@brocade.com
BROCADE FASTIRON CX SERIES POWER AND THERMAL SPECIFICATIONS
Max Current at 
100 VAC (Amps)
Max Current at 
200 VAC (Amps)
Max Total Power 
Draw
3
 (Watts)
Max System Power 
Draw
4
 (Watts)
Max Thermal 
Output
5
 (BTU/Hr)
Energy Efficiency 
(Watts/Gbps)
2
FCX 624
1
0.9
0.6
92
92
312.8
1.4
FCX 648
1
1.2
0.7
112
112
421.6
1.3
FCX 624S
1.09
0.51
94
94
319
1.23
FCX 624S-F
1.00
0.58
102
102.1
348
1.34
FCX 648S
1.39
0.63
122
122
416
1.22
FCX 624S-HPOE
6
1.09
0.58
509
107
365
1.41
FCX 648S-HPOE
6
1.72
0.94
970
167
570
1.67
1
 With 4-port 10 GbE module installed and one power supply.
2
 Calculated using switch data rate.
3
 Total power drawn from the source and consumed by the switch and 
attached PoE devices. Class 3 devices assumed on all ports.
4
 Power drawn from the source and consumed only by the switch.
5
 Thermal output of the switch.
6
 With two power supplies installed.
Mechanical
Enclosure
FCX 624, FCX 648: front-to-back airflow (reversible)
FCX 624S, FCX 624S-F, FCX 648S, FCX 624S-HPOE,
FCX 648S-HPOE: side-to-back airflow
1U, 19-inch EIA-compliant, power from non-port side
Size
FCX 624 and FCX 648 switch models:
Width: 44.0 cm (17.3 in.)
Height: 4.4 cm (1.7 in.)
Depth: 43.5 cm (17.2 in.)
FCX 624S, FCX 624S-F, and FCX 648S switch models:
Width: 44.0 cm (17.3 in.)
Height: 4.4 cm (1.7 in.)
Depth: 38.6 cm (15.2 in.)
FCX 624S-HPOE and FCX 648S-HPOE
switch models:
Width: 44.0 cm (17.3 in.)
Height: 4.4 cm (1.7 in.)
Depth: 44.0 cm (17.3 in.)
Weight
FCX 624: 5.35 kg (11.79 lb)
FCX 648: 5.71 kg (12.59 lb)
FCX 624S, FCX 624S-F, and FCX 648S switch models:
4.0 kg (8.8 lb)
FCX 624S-HPOE and FCX 648S-HPOE switch models:
4.5 kg (9.9 lb)
Environment
Temperature
Operating temperature: 32° to 104°F (0° to 45°C)
Storage temperature: -23° to 158°F (-25° to 70°C)
Humidity
Relative humidity: 5% to 95%, non-condensing
Altitude
Storage altitude: 10,000 ft (3000 m) maximum
Acoustic
51 to 63 dB
Power
Power supplies
Up to two internal, redundant, field-replaceable,
load-sharing AC power supplies
Power inlet
C13
Input voltage
Typical 100 to 240 VAC
Input line frequency
50 to 60 Hz
Compliance/Certification
Electromagnetic
emissions
FCC Class A (Part 15); EN 55022/CISPR-22 Class A;
VCCI Class A
ICES-003 Electromagnetic Emission; AS/NZS 55022;
EN 61000-3-2 Power Line Harmonics; EN 61000-
3-3 Voltage Fluctuation and Flicker; EN 61000-6-3
Emission Standard (Supersedes: EN 50081-1)
Safety
CAN/CSA-C22.2 No. 60950-1-3; UL 60950-1;
IEC 60950-1; EN 60950-1 Safety of Information
Technology Equipment; EN 60825-1 Safety of
Laser Products—Part 1: Equipment Classification,
Requirements and User’s Guide; EN 60825-2 Safety
of Laser Products—Part 2: Safety of Optical Fibre
Communication Systems
Immunity
EN 61000-6-1 Generic Immunity and Susceptibility
(this supersedes EN 50082-1); EN 55024 Immunity
Characteristics (this supersedes EN 61000-4-2 ESD);
EN 61000-4-3 Radiated, radio frequency,
electromagnetic field; EN 61000-4-4 Electrical
fast transient; EN 61000-4-5 Surge; EN 61000-4-6
Conducted disturbances induced by radio-frequency
fields; EN 61000-4-8 Power frequency magnetic field;
EN 61000-4-11 Voltage dips and sags
Environmental
regulatory
compliance
RoHS-compliant (6 of 6); WEEE-compliant