Elmo DSP 402 User Manual

Page of 116
  The value of the profile deceleration is reflected in the DC command, to which the 
range and restrictions are ultimately submitted (refer to the 
SimplIQ
 Command 
Reference Manual). 
 
Object 0x6085: Quick stop deceleration  
The quick stop deceleration is the deceleration used to stop the motor if the Quick Stop 
command is given and the quick stop option code (see 605Ah) is set to 2. The quick stop 
deceleration 
is given in the same units as the profile acceleration
 
Object description: 
Index 6085h 
Name 
Quick stop deceleration 
Object code 
VAR 
Data type 
UNSIGNED32 
Category Optional 
 
Entry description: 
Access Read/write 
PDO mapping 
No 
Value range 
UNSIGNED32 
Default value 
Object 0x6086: Motion profile type  
This object is used to select the type of motion profile used to perform a profile move. 
 
Object description: 
Index 6086h 
Name 
Motion profile type 
Object code 
VAR 
Data type 
INTEGER16 
Category Mandatory 
 
Entry description: 
Access Read/write 
PDO mapping 
No 
Value range 
INTEGER16 
Default value 