Panasonic WV-CW504F User Manual

Page of 44
15
Preparations
When  installing  the  camera  on  a  wall  or  a  ceiling,  there  are  two  methods  as  specified  below.  
(+ Next page)
 •  Using a two-gang junction box
 •  Using the mounting base WV-Q115
Refer to all work related to the installation of this product to qualified service personnel or system 
installer. 
 •  The mounting base WV-Q115 is optional for WV-CW504F, WV-CW504FK. Use the screws sup-
plied with the camera mount bracket. 
 •  The mounting base WV-Q115 is supplied with WV-CW504S, WV-CW504SK. Use the screws
supplied with this product. 
Important:
 •  Prepare the mounting screw according to the material of the area where the camera attach-
ment (accessory) is to be installed. In this case, wood screws and nails should not be used. For 
mounting a camera on a concrete ceiling, use an anchor bolt (M4) or an AY plug bolt (M4) for 
securing. 
    (Recommended tightening torque M4: 1.6 N·m {1.18 lbf·ft})
 •  When using the provided camera attachment, make sure that either of the arrow marks faces
upward. 
 •  Required pull-out capacity of a single screw/bolt is 196 N {44.06 lbf} or more.
 •  If a ceiling board such as plaster board is too weak to support the total weight, the area shall
be sufficiently reinforced. 
 •  When using an optional mounting bracket, refer to the operating instructions of the bracket in
use. 
The mounting conditions of the camera mount bracket are described as follows: 
Installation 
place
Applicable mount  
bracket
Recommended 
screw
Number 
of screw
Minimum pull-out 
strength 
(per 1 pc.)
Ceiling/wall
(Two-gang junction box)
M4 or equivalent
4 pcs.
196 N {44.06 lbf}
Ceiling/wall
WV-Q115 
(approx. 350 
g {0.77 lbs})
M4 or equivalent
4 pcs.
196 N {44.06 lbf}
Ceiling
WV-Q169 
(approx. 700 
g {1.55 lbs})
*
*  Make sure that the installed mount bracket can support more than 5 times of the weight of the 
camera.