Flaw compensation [PIX OFF]
Flaws in the displayed camera image are corrected. Up to 16 points can be corrected. 
Follow the procedure below. 
Step 1
Move the cursor to "PIX OFF" and press the setting button. 
 
→  The "PIX OFF" screen appears. 
Step 2
Select a number (1 to 16) with which a pixel compensation point is registered and press the setting button. 
 
→  The pixel compensation positioning screen appears. 
Step 3
Use the up, down, right, and left buttons to move the crosshair cursor to the center of the flaw to be corrected and press the setting 
button. 
 
→  The flaw is corrected and the pixel compensation point is registered. The "PIX OFF" screen appears again. "*" is attached at the 
right side of the number when registration is completed. The coordinate is expressed in figures. 
Note:
 •  To clear the registered pixel compensation point, move the cursor to the number with which the target pixel compensation point
is registered on the "PIX OFF" screen and press the setting button. The pixel compensation positioning screen appears, and then 
hold down the right and left buttons for more than 2 seconds simultaneously. The "PIX OFF" screen appears, the pixel compensa-
tion point is cleared, and "*" at the right side of the number disappears. 
Default resetting [CAMERA RESET]
The settings in the setup menu are restored to the default settings. 
The default settings are restored by moving the cursor to "PUSH SW" of "CAMERA RESET" and holding down the right, left, and set-
ting buttons for more than 2 seconds simultaneously. 
Note:
 •  The data of the back focus setting and registered pixel compensation points is not cleared.
Serial number viewing [SER.NO.]
The serial number of this unit appears. 
   **SPECIAL SETUP**
CHROMA GAIN   ...
|
...128
AP GAIN       ...
|
... 32
PEDESTAL      ...
|
... 32
HUE           ...
|
...  0
              -     +
PIX OFF
CAMERA RESET  PUSH SW
 SER.NO. XXXXXXXX
 RET TOP END
"SPECIAL SETUP" screen
"PIX OFF" screen
Pixel compensation positioning screen
      **PIX OFF**
  1     2     3     4   
  5     6     7     8
  9    10    11    12
 13    14    15    16
 000 000