Troubleshooting
Before asking for repairs, check the symptoms with the following table. 
Contact your dealer if a problem cannot be solved even after checking and trying the solution in the 
table or a problem is not described below. 
Symptom
Cause/solution
Reference 
pages
No image displayed
• Are the power cord and coaxial cable
connected appropriately?
→  Check whether the connection is 
appropriately established. 
30
• Is the adjusting monitor connected ?
→  Check whether connection is estab-
lished.
24
• Is the monitor brightness appropriately
adjusted, or is the contrast appropriately 
adjusted?
→  Check whether the monitor settings 
are appropriate.
• Were the shock absorbers in the dome
cover already removed? 
→  Confirm whether the shock absorbers 
have been already removed. 
Blurred image
• Is the dome cover free from contamina-
tion and/or flaws? 
→  Check the dome cover. 
• Is the focus adjusted correctly?
→  Check if the focus is adjusted correct-
ly. 
25
• Is the lens of the camera soiled with dirt
or dust?
→  Check whether the lens of the camera 
is clean. 
Damaged power cord 
sheathing
The power cord and connector is dam-
aged. Use of the damaged cord or con-
nector may cause electric shock or fire. 
Turn off the power immediately and request 
repair to your dealer. 
Heated portion of power line 
consisting of power cord 
during use
Warmed power cord or loos-
ened connection by bending 
or stretching during use