Panasonic AW-HE130K User Manual

Page of 126
The genlock adjustment is performed to achieve phase alignment by
applying external synchronization (genlock) when a multiple number of
cameras will be used or when the unit will be used in combination with
other devices.
This unit supports BBS (Black Burst Sync) and tri-level sync external
synchronization signals.
Ask your dealer to perform this adjustment.
(Use a dual-trace oscilloscope for the adjustment.)
Horizontal phase adjustment
Observe the waveforms of the external sync signal input (tri-level sync
signal) and video signal output on the dual-trace oscilloscope, and use
the wireless remote control or controller to bring the horizontal phase
into alignment.
External sync signal 
input
(tri-level sync signal)
Video signal output
Bring the horizontal 
phase into alignment.
Example: When the tri-level sync phase is adjusted
When performing operations from a wireless 
remote control
2. Press the <4> or <5> button to bring the cursor to 
[System].
   Top Menu 
 Camera      Scene: Scene1
 System
 Maintenance
3. Press the <M> button.
The [System] screen appears.
    System 
 Genlock
 Output
 Others
 Return
4. Press the <4> or <5> button to bring the cursor to 
[Genlock], and press the <M> button.
The [Genlock] sub-menu is displayed.
     Genlock 
 Horizontal Phase        0
 Horizontal Phase Step   1
 Return
5. Press the <4> or <5> button to bring the cursor to 
[Horizontal Phase], and press the <M> button.
The [Horizontal Phase] value starts blinking.
6. Press the <4> or <5> button to change the [Horizontal 
Phase] value, adjust the value so that the horizontal 
phase is brought into alignment, and press the <M
button.
The extent of the phase adjustment can be selected using [Horizontal
Phase Step].
7. Press and hold the <MENU> button for about 2 seconds.
The camera menu display is exited.
When performing operations from a controller
These operations can be performed using the camera menus by
following the operation steps in “Basic operations” “Basic operations”
Genlock adjustment