Magellan MG-6060 User Manual

Page of 48
Paradox Magellan Systems
 
25
Auxiliary Panic: Panic keys [4] and [6] (page 23) or the 
appropriate button(s) on a remote control (page 18) have 
been pressed.
Fire Panic: Panic keys [7] and [9] (page 23) or the 
appropriate button(s) on a remote control (page 18) have 
been pressed.
Recent Closing: Reports when an alarm is generated after 
arming the system within period defined by the Recent 
Close Delay (see page 28).
Section [140]
Auto-zone Shutdown: A zone communicates more than the 
programmed number of transmissions in a single armed 
period (see page 15). 
Duress: A Duress access code is keyed in (see page 12). 
Paramedical alarm
Future use
Zone Tamper Report Codes
Section [141] to [144]
A report code can be programmed for each of the 16 available 
zones. Whenever a tamper or wire fault occurs on a zone, the 
Magellan console can send the appropriate report code to the 
central station identifying which zone was tampered.
If Tamper Recognition (see page 22) is disabled, the 
console will not report the occurrence of any tampers, 
wire faults or tamper restores.
Zone Tamper Restore Report Codes
Sections [145] to [148]
A report code can be programmed for each of the 16 available 
zones. Whenever a tampered zone is restored, the Magellan 
console can send the appropriate report code to the central 
station identifying which zone has been restored.
If Tamper Recognition (see page 22) is disabled, the console 
will not report the occurrence of any tampers, wire faults or 
tamper restores.
System Trouble Report Codes
Section [149] to [151]
Whenever the system generates one of the instances listed 
below, the console can send the appropriate report code to the 
central station identifying the type of system trouble.
Section [149]
Console Tamper: A tamper has been detected on the 
console itself (see Console Tamper Supervision on page 
31).
AC Failure: Magellan has detected a loss of AC power. 
Transmission of this report code can be delayed (see Power 
Failure Report Delay on page 29).
Battery Failure: The backup battery is disconnected or 
battery voltage is 
d less than or equal to)6.9V.
Timer Loss: The console has detected a loss in time or clock 
failure.
Section [150]
Future use
Fail To Communicate: The Magellan console has failed all 
attempts to communicate with the central station. The report 
code will be transmitted upon the next successful attempt.
Wireless Low Battery: The battery voltage of an Omnia 
wireless transmitter (motion detector or contact switch) has 
dropped below recommended limits.
Tx Supervision Loss: Check-in Supervision (page 22) has 
been enabled and a transmitter is no longer communicating 
with the system.
Section [151]
Future use
Future use
Future use
Future use
System Trouble Restore Codes
Sections [152] to [154]
Whenever the system restores one of the troubles listed in 
sections [149] and [150] (see System Trouble Report Codes on 
page 25), the Magellan console can send the appropriate report 
code to the central station identifying the type of system trouble 
restored. If Telephone Line Monitoring is enabled (see page 28), 
use the first two digits to program a TLM Restore report code 
that the console can transmit.
Special Reporting Codes
Sections [155] and [156]
Whenever the system generates one of the instances listed 
below, the Magellan console can send the appropriate report 
code to the central station identifying the type of system 
occurrence.
Section [155]
Cold Start: The console was completely shutdown (no 
battery, no AC) and then was restarted.
Test Report: A test report has been generated automatically 
(see page 29).
Future use
WinLoad Logout: The console has ended communication 
with WinLoad.
Section [156]
Installer logon: Installer has entered the programming 
mode.
Installer Logout: Installer has exited the programming mode.
Closing Delinquency: The last time the system was armed is 
greater than the programmed Closing Delinquency timer 
(page 21).
Future use
Console Telephone Numbers
Magellan can dial up to two different central station telephone 
numbers and one Pager telephone number. You can enter any 
digit from 0 to 9 and any special keys or functions (see Table 8 
on page 26) up to a maximum of 32 digits. If the number is less 
than 32 digits, press the left [
ACTION
] key (
OK
) to save the 
message.