Auto-Test Report
Section [071]: 001 to 255 days; 000 = Disabled; Default =
Disabled
Section [084]: Time (HH:MM)
The Magellan console will transmit the Test Report report code
programmed into section [153] after the number of days
programmed into section [071] has elapsed at the time
programmed into section [084]. Use the 24-hour clock to
program the time (i.e. 6:30PM = 18:30). The first Test Report will
be transmitted within 24 hours after the feature is enabled at the
time programmed in [084].
programmed into section [153] after the number of days
programmed into section [071] has elapsed at the time
programmed into section [084]. Use the 24-hour clock to
program the time (i.e. 6:30PM = 18:30). The first Test Report will
be transmitted within 24 hours after the feature is enabled at the
time programmed in [084].
Example: Section [071] = 005 and section [084] = 13:00. The first
Test Report will be sent at 1 PM that day and then the report will
be sent every 5 days at 1 PM.
Test Report will be sent at 1 PM that day and then the report will
be sent every 5 days at 1 PM.
Power Failure Report Delay
Section [070]: 001 to 255 minutes; 000 = Disabled;
Default = 15 minutes
The Magellan console will transmit the AC Failure report code
programmed in section [149] after the Power Failure Report
Delay period has elapsed.
programmed in section [149] after the Power Failure Report
Delay period has elapsed.
Disarm Reporting Options
Section [093]: Option [5]
Option [5] OFF = Always Report Disarming
Option [5] ON =
Option [5] OFF = Always Report Disarming
Option [5] ON =
Report Disarming only after Alarm (Default)
With option [5] OFF, the Magellan console will send the
Disarming report codes (see page 24) to the central monitoring
station every time the system is disarmed. With option [5] ON,
the console will send the Disarming report codes to the central
monitoring station when the system is disarmed following an
alarm.
Disarming report codes (see page 24) to the central monitoring
station every time the system is disarmed. With option [5] ON,
the console will send the Disarming report codes to the central
monitoring station when the system is disarmed following an
alarm.
Zone Restore Report Options
Section [094]: Option [2]
Option [2] OFF = Report On Bell Cut-Off (Default)
Option [2] ON =
Option [2] OFF = Report On Bell Cut-Off (Default)
Option [2] ON =
Report On Zone Closure
With option [2] OFF, the Magellan console will send the Zone
Alarm Restore report codes (see page 24) to the central
monitoring station when the zone has returned to normal and the
Bell Cut-Off Timer (see page 22) has elapsed. With option [2]
ON, the console will send the Zone Alarm Restore report codes
to the central station as soon as the zone returns to normal or
when the system is disarmed.
Alarm Restore report codes (see page 24) to the central
monitoring station when the zone has returned to normal and the
Bell Cut-Off Timer (see page 22) has elapsed. With option [2]
ON, the console will send the Zone Alarm Restore report codes
to the central station as soon as the zone returns to normal or
when the system is disarmed.