Magellan MG-6060 User Manual

Page of 48
Paradox Magellan Systems
 
29
Auto-Test Report
Section [071]: 001 to 255 days; 000 = Disabled; Default = 
Disabled   
Section [084]: Time (HH:MM)
The Magellan console will transmit the Test Report report code 
programmed into section [153] after the number of days 
programmed into section [071] has elapsed at the time 
programmed into section [084]. Use the 24-hour clock to 
program the time (i.e. 6:30PM = 18:30). The first Test Report will 
be transmitted within 24 hours after the feature is enabled at the 
time programmed in [084]. 
Example: Section [071] = 005 and section [084] = 13:00. The first 
Test Report will be sent at 1 PM that day and then the report will 
be sent every 5 days at 1 PM.
Power Failure Report Delay
Section [070]: 001 to 255 minutes; 000 = Disabled; 
Default = 15 minutes
The Magellan console will transmit the AC Failure report code 
programmed in section [149] after the Power Failure Report 
Delay period has elapsed. 
Disarm Reporting Options
Section [093]: Option [5]
Option [5] OFF = Always Report Disarming
Option [5] ON =
Report Disarming only after Alarm (Default)
With option [5] OFF, the Magellan console will send the 
Disarming report codes (see page 24) to the central monitoring 
station every time the system is disarmed. With option [5] ON, 
the console will send the Disarming report codes to the central 
monitoring station when the system is disarmed following an 
alarm.
Zone Restore Report Options
Section [094]: Option [2]
Option [2] OFF = Report On Bell Cut-Off (Default)
Option [2] ON =
Report On Zone Closure
With option [2] OFF, the Magellan console will send the Zone 
Alarm Restore report codes (see page 24) to the central 
monitoring station when the zone has returned to normal and the 
Bell Cut-Off Timer (see page 22) has elapsed. With option [2] 
ON, the console will send the Zone Alarm Restore report codes 
to the central station as soon as the zone returns to normal or 
when the system is disarmed.