Preparation - General information
–
Before connecting the battery or switching the main power supply on, unplug the in-
ternal siren for the time of the installation (small plug with cable, directly on the left
lower side of the display).
lower side of the display).
–
If the internal buzzer starts beeping: Press
to silence it.
–
To exit the system at any time: Press and hold the button
.
Reset back to factory setting:
–
Reset all pins and numbers: Press
200
9
.
–
Reset all individually changed parameters: Press
200
10
.
Language setting
1. Press
Ctrl
simultaneously
t the “Local Mode” opens.
2. Scroll with the buttons
2. Scroll with the buttons
/
to the posi-
tion “Language” and press
to select.
3. Scroll with the buttons
/
to the lan-
guage you prefer and press
to save.
4. To exit press and hold the button
.
Start programming
Programming the system (steps 2 -10) is
only possible in installer mode. To get into
installer mode the system must be disarmed!
only possible in installer mode. To get into
installer mode the system must be disarmed!
1. Press
user code “147258”
t the displays shows: “CLIENT:USER”.
2. Press
2. Press
installer code “258369”
t the displays shows: “ISTALLER:USERS”.
Clock setting
1. Set time: press
26
1
”
HHMM
”
2. Set weekday: press
26
2
”
DAY
”
(Sunday = 1, Monday = 2…etc.)
3. Set date: press
26
3
”
DDMMYY
”
4. Activate automatic daylight saving (default
Europe GMT+1): press
26
4
1
Detectors
Learn the wireless detectors (max.16), be-
fore installing, to the panel. Default settings:
- Zones 1 and 2 are delayed for entry route.
- Zones 3 - 8 are set for normal zones.
- Zones 9 - 16 are set for Stay zones.
We recommend using:
- Zone 1: magnet contact from the entry
fore installing, to the panel. Default settings:
- Zones 1 and 2 are delayed for entry route.
- Zones 3 - 8 are set for normal zones.
- Zones 9 - 16 are set for Stay zones.
We recommend using:
- Zone 1: magnet contact from the entry
door.
- Zone 2: first motion detector for the surveil-
lance of the entry area (control panel).
1. For zone 1: press
164
1
t the keypad will start beeping to indicate
that learn mode has been activated.
2. Press the tamper contact on the detector
or remove the magnet from the door
contact
contact
t it will send a transmission signal. The
panel will confirm if a detector is found
with the message “Found”.
with the message “Found”.
3. Press
to confirm.
4. Repeat actions 1 - 3 to follow up for the
zones 2 - 16 (use the navigation button
to switch to the next zone).
to switch to the next zone).
If a detector could not be learned it is either
already learned to the panel, or the transmis-
sion signal was not received - try again.
Already learned detectors can be checked in
“Find Detector” mode: press
already learned to the panel, or the transmis-
sion signal was not received - try again.
Already learned detectors can be checked in
“Find Detector” mode: press
166
Entry delay time
The entry delay time is set by default to 20
sec. To change the time (0-9999 seconds)
per zone:
sec. To change the time (0-9999 seconds)
per zone:
1. Zone 1: press
144
1
”seconds”
2. Zone 2: press
144
2
”seconds”
Exit delay time
The exit delay time is set by default to 30
sec. To change the time (0 - 255 seconds)
per area:
Area A: press
sec. To change the time (0 - 255 seconds)
per area:
Area A: press
60
1
”seconds”
Remote control
Learn a remote control (max. 16) to the
system starting with user number 21 - 25.
Default setting:
system starting with user number 21 - 25.
Default setting:
User 21:
ARM User 22:
DISARM
User 23:
STAY
User 25:
FREE
User 24:
(
simultaneously ) PANIC/SOS
1. Remote control 1: press
18
21