Siemens IC60 User Manual

Page of 40
 
Siemens Building Technologies
 
 
Fire Safety & Security Products 
 
01.2008
 
 
EN 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
x
 
 
Preparation - General information 
– 
Before connecting the battery or switching the main power supply on, unplug the in-
ternal siren for the time of the installation (small plug with cable, directly on the left 
lower side of the display). 
– 
If the internal buzzer starts beeping: Press 
 to silence it. 
– 
To exit the system at any time: Press and hold the button 
.
 
Reset back to factory setting: 
– 
Reset all pins and numbers: Press 
200
9
– 
Reset all individually changed parameters: Press 
200
10
. 
 
 
Language setting
 
1. Press 
Ctrl
 simultaneously  
t the “Local Mode” opens. 
2. Scroll with the buttons 
/
 to the posi-
tion “Language” and press 
 to select. 
3. Scroll with the buttons 
/
 to the lan-
guage you prefer and press 
 to save. 
4. To exit press and hold the button 
.
 
 
Start programming
 
Programming the system (steps 2 -10) is 
only possible in installer mode. To get into 
installer mode the system must be disarmed! 
1. Press 
user code “147258
 
t  the displays shows: “CLIENT:USER”. 
2. Press 
installer code “258369
 
t the displays shows: “ISTALLER:USERS”. 
 
Clock setting
 
1. Set time: press 
26
1
HHMM
 
2. Set weekday: press 
26
2
DAY
 
(Sunday = 1, Monday = 2…etc.) 
3. Set date: press 
26
3
DDMMYY
 
4. Activate automatic daylight saving (default 
Europe GMT+1): press 
26
4
1
 
 
Detectors 
Learn the wireless detectors (max.16), be-
fore installing, to the panel. Default settings: 
- Zones 1 and 2 are delayed for entry route. 
- Zones 3 - 8 are set for normal zones. 
- Zones 9 - 16 are set for Stay zones. 
We recommend using: 
- Zone 1: magnet contact from the entry 
door. 
- Zone 2: first motion detector for the surveil-
lance of the entry area (control panel). 
1. For zone 1: press 
164
1
 
t the keypad will start beeping to indicate 
that  learn mode has been activated. 
2. Press the tamper contact on the detector 
or remove the magnet from the door  
contact 
t it will send a transmission signal. The 
panel will confirm if a detector is found 
with the message “Found”. 
3. Press 
 to confirm. 
4. Repeat actions 1 - 3 to follow up for the 
zones 2 - 16 (use the navigation button   
to switch to the next zone). 
If a detector could not be learned it is either 
already learned to the panel, or the transmis-
sion signal was not received - try again.  
Already learned detectors can be checked in 
“Find Detector” mode: press 
166
 
 
Entry delay time
 
The entry delay time is set by default to 20 
sec. To change the time (0-9999 seconds) 
per zone: 
1. Zone 1: press 
144
1
seconds
 
2. Zone 2: press 
144
2
seconds
 
 
Exit delay time
 
The exit delay time is set by default to 30 
sec. To change the time (0 - 255 seconds) 
per area: 
Area A: press 
60
1
seconds
 
 
Remote control 
Learn a remote control (max. 16) to the  
system starting with user number 21 - 25.  
Default setting: 
User 21: 
 ARM  User 22: 
 DISARM 
User 23: 
 STAY
User 25: 
 FREE
User 24: 
 
  
(
simultaneously ) PANIC/SOS 
 
1. Remote control 1: press 
18
21