Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1012 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Major Alarm Inquiry Test (#142)
The Major alarm raised by a DS1 Interface circuit pack indicates that the average bit error rate 
on the DS1 facility is greater than 1/1000. The Major Alarm Inquiry test is used to determine that 
the received DS1 bit error rate is greater than 1/1000. When D4 framing mode is selected, the 
DS1 Interface circuit pack takes 16 seconds to recognize and report a Major alarm and 16 
seconds to recognize and report that a Major alarm condition is cleared. If ESF framing mode is 
selected, the DS1 Interface circuit pack takes 10 seconds to recognize and report a Major alarm 
and 10 seconds to recognize and report that a Major alarm condition is cleared.
When the DS1 Interface circuit pack detects a Major alarm, it will send a MAJOR-ALARM 
message to the maintenance software. After the maintenance software receives a 
MAJOR-ALARM message, the Major Alarm Inquiry test is initiated to confirm the Major alarm on 
the DS1 Interface circuit pack. The Inquiry test will be run every 10 minutes until the Major alarm 
is cleared. The maintenance software places all trunks on the circuit pack in the out-of-service 
state if the Major alarm persists for more than 20 minutes.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an 
incorrect board is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use add ds1 
location to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If so, the board was shut 
down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, enter 
busyout board
4. Enter reset board
5. Enter release board
6. Enter test board long
This should re-establish the linkage between the internal ID and the 
port.
Table 347: Test #141 Yellow Alarm Inquiry Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3