Communication Manager Maintenance-Object Repair Procedures
1014 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
FAIL
The DS1 Interface circuit pack detects a Major alarm. The DS1 bit error rate 
is greater than 1/1000.
1. The performance of DS1 link between DS1 Interface circuit pack and 
remote DS1 endpoint is very poor. If the DS1 Interface circuit pack is 
TN767, enter list measurement ds1-log location to read the 
error seconds measurement.
2. Verify that both endpoints of the DS1 link are administered using the 
same signaling mode, framing mode, and line coding.
3. If the DS1 interface circuit pack connects to a T1 facility, call the vendor 
of the T1 carrier to diagnose the remote DS1 endpoint. If the DS1 
interface circuit pack connects directly to a switch, call the system 
technician of the remote switch to diagnose the DS1 endpoint.
4. Check the physical connectivity of the DS1 pack and of the cable.
5. Replace the local DS1 interface circuit pack, and repeat the test.
PASS
No Major alarm is detected in DS1 Interface circuit pack.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an 
incorrect board is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use add ds1 
location to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If so, the board was shut 
down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, enter busyout 
board
4. Enter reset board
5. Enter release board
6. Enter test board long
This should re-establish the link between the internal ID and the port.
Table 348: Test #142 Major Alarm Inquiry Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2