Avaya 03-300430 User Manual

Page of 2574
DS1-BD (DS1 Interface Circuit Pack)
Issue 1 June 2005
1019
 
1 to 88
FAIL
The DS1 interface circuit pack detected a slip alarm. The error code 
equals the number of slips detected by the DS1 interface circuit pack 
since the last slip alarm inquiry test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the DS1 interface circuit pack is a TN767, enter list 
measurement ds1-log location to read the error seconds 
measurement.
3. Verify that both endpoints and all intermediate equipment of the DS1 
link are administered using the same signaling mode, framing mode, 
and line coding.
4. If the DS1 interface circuit pack connects to a T1 facility, call the 
vendor of the T1 carrier to diagnose the remote DS1 endpoint. If the 
DS1 interface circuit pack connects directly to a switch, call the 
system technician of the remote switch to diagnose the DS1 endpoint.
5. Check the active alarm and error logs for recent alarms and errors 
against the synchronization (SYNC). Follow the suggested repair 
procedure for these errors.
6. Check the physical connectivity of the DS1 pack and of the cable.
7. If this continues to fail, escalate this problem.
 
PASS
No Slip alarm is detected on the DS1 Interface circuit pack.
Table 350: Test #144 Slip Alarm Inquiry Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3