Communication Manager Maintenance-Object Repair Procedures
1032 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1015
ABRT
Ports on the DS1 Interface circuit pack have not been busied out to 
out-of-service.
1. Enter busyout board location to put all trunks or ports of the DS1 
Interface circuit pack into the out-of-service state.
2. Retry the command.
1039
ABRT
The DS1 Interface circuit pack is providing timing for the system. Executing 
this test could cause major system disruption.
If the DS1 Interface circuit pack needs to be tested, set the synchronization 
reference to another DS1 Interface circuit pack or to the Tone-Clock circuit 
via the following command sequence:
1. Enter disable synchronization-switch
2. Enter enable synchronization-switch set 
synchronization location
3. Enter enable synchronization-switch
1950
ABRT
Another loop-back/span test is already executing on the DS1 board or the 
board is in a network requested loop-back mode (Line loop back or Payload 
loop back). The hardware error log indicates whether a Customer Loopback 
Jack test, Far CSU Loopback test, or the One-Way Span test is executing or 
if the board is in line loop-back or payload loop-back mode. Only one 
long-duration loop-back/span test can be active at a given time. Thus, if a 
loop-back/span test is already active, that test must be deactivated via test 
ds1-loop location end-loopback/span-test in order to execute 
this test.
1951
ABRT
The CSU Repeater Loopback test could not be executed because the 120A 
CSU module/T1 sync splitter was not physically installed. Physically connect 
the 120A1 CSU module/T1 sync splitter to the TN767E board on the back of 
the port carrier.
Table 355: Test #1211 CSU Repeater Loop-Back Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 4