Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1078 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
The DS1 converter circuit pack can be placed in any regular slot in a PN carrier. However, the 
DS1 converter circuit pack can only be placed in slots 1 and 21 in a Switch Node (SN) carrier. 
The DS1 converter circuit pack is not connected to the TDM bus or the SN backplane. 
Communication to the circuit pack is done through the connected EI or the SNI circuit packs. 
Therefore, there is considerable interaction between the DS1 converters and the connected EIs 
and the SNIs. A special “Y” cable connects the DS1 converter circuit pack to the Fiber Endpoint 
and to the facilities.
Note:
Note:
The two DS1 converter boards, TN1654 and TN574, use unique “Y” cables that 
are incompatible with each other.
The TN573 SNI circuit pack is incompatible with the TN1654 board. A TN573B (or 
higher-suffixed) SNI board must be used when connecting to a TN1654 board. The TN573B 
SNI board is fully backward compatible with the TN573 board and can be connected to either 
TN1654 or TN574 boards.
Note:
Note:
A TN573B (or higher-suffixed) board must be used when connecting a SNI board 
to a TN1654 board. Error 125 will be logged and an on-board minor alarm will be 
generated against the SNI board if it is incompatible with the TN1654 circuit pack.
connections in a direct-connect PNC configuration and between the CSS and an PN in a 
critical-reliability system configuration (duplicated PNC).
Figure 55: DS1 converter connection to EIs and SNIs
Metallic or Fiber Connection
DS1CONV
DS1 Facilities
Network
EI
or
SNI
EI
DS1CONV
Metallic or Fiber Connection