Upgrading TN574 DS1 Converter Circuit Packs 
in a Fiber-Link to TN1654s — Duplicated PNC
!
WARNING:
WARNING:
Do not power down a Switch Node carrier to replace a circuit pack.
!
WARNING:
WARNING:
In duplicated PNC configurations, one DS1 converter complex in the fiber-link 
serves as the active and the second DS1 converter complex serves as the 
standby. Each DS1 Converter complex consists of two TN574 boards or two 
TN1654 boards. A TN574 cannot be combined with a TN1654 in the same DS1 
converter complex. It is also required that all four DS1 converter boards and 
interconnecting facilities that serve an PN be of the same type. Note, however, 
that TN574 and TN1654 boards can coexist within the same system, they just 
cannot be in the same fiber-link.
!
WARNING:
WARNING:
The two DS1 converter boards, TN1654 and TN574, use unique “Y” cables that 
are incompatible with each other.
!
WARNING:
WARNING:
A TN573B (or higher-suffixed) board must be used when connecting a SNI board 
to a TN1654 DS1 Converter board.
Enter change circuit-packs 
cabinet #. Update the screen to 
show that TN1654 boards are now 
being used instead of TN574 boards. 
Also update the connected SNI, if 
applicable, to suffix B.
Cabinet # represents the cabinet associated with a 
DS1 converter board. The change circuit-packs 
screen needs to be updated for both DS1 converter 
boards. Also, if needed, re-add translations for 
connected EI boards.
Enter add fiber-link fiber# to 
re-add the fiber-link using TN1654 DS1 
converter circuit packs. 
Fiber# represents the fiber-link number associated 
with the TN574 DS1 converter complex that is being 
upgraded to a TN1654 DS1 converter complex
Enter test alarms long clear 
for category exp-intf.
Wait 5 minutes for SNI-BD, FIBER-LK 
AND DS1C-BD alarms to clear, or 
enter clear firmware-counters 
a-pnc
Steps
Comments
 2 of 2