Enter change system-parameters 
duplication. Enter y in Enable 
Operation of PNC Duplication 
field.
Enable PNC duplication.
Enter add fiber-link fiber# to 
re-add the fiber-link using TN1654 DS1 
converter circuit packs.
fiber# represents the fiber-link number 
associated with the TN574 DS1 converter 
complexes that are being upgraded to TN1654 
DS1 converter complexes.
Enter test alarms long clear for 
category exp-intf.
Wait 5 minutes for SNI-BD, SNI-PEER, 
FIBER-LK and DS1C-BD alarms to 
clear, or enter clear 
firmware-counters a-pnc | 
b-pnc.
Enter status pnc.
If either PNC’s state of health is not “functional”, 
consult the PNC-DUP section of the Maintenance 
Manual.