Avaya 03-300430 User Manual

Page of 2574
DS1C-BD
Issue 1 June 2005
1091
 
8.
Remove the DS1- CONV 
hardware.
Remove the 4 TN574 or TN1654 DS1-CONV 
circuit packs and Y-cables.
The TN1654 and TN574 DS1-CONV boards use 
unique “Y” cables that are incompatible with 
each other. Reuse these cables only with the 
proper circuit pack.
9.
Install fiber-optic cable.
Add the lightwave transceivers (multimode 
9823A or single-mode 300A) to match the 
lightguide fiber. Add these to the EIs and SNIs 
formerly connected to the DS1 converter circuit 
packs. Connect the lightwave transceivers with 
lightguide fiber.
10.
Check fiber-optic cable 
connections.
Ensure that the fiber-optic cables are securely 
connected to the lightwave transceivers that are 
attached to the designated circuit packs through 
the connections on the back of the cabinet.
11.
add fiber-link n
Administer the new EI/SNI fiber connection.
12.
change system-parameters 
duplication
Enable PNC duplication by changing the 
Enable Operation of PNC Duplication 
field to y.
13.
Enter test alarms long 
clear for category exp-intf.
14.
Wait 5 minutes.
SNI-BD, SNI-PEER, FIBER-LK and EXP-INTF 
MOs need time to clear (or enter clear 
firmware-counters a-pnc or b-pnc)
15.
Enter status pnc.
If either PNC’s state of health is not 
functional, consult the PNC-DUP MO.
Table 370: Convert from DS1-CONV to direct-connect fiber in a duplicated PNC  
Step Command/Step
Description
 2 of 2