Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1102 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
The reset sequence will take about one minute to complete.
Table 374: Test #787 Reset Board
 
Error 
Code
Test 
Result
Description / Recommendation
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABRT
The timer could not be set before sending the downlink message 
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2316
ABRT
Fiber link is not administered. 
Use add fiber-link to administer the DS1 converter fiber link.
2321
ABRT
DS1 converter circuit pack is not busied out. 
Use busyout board to busyout the DS1 converter circuit pack.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
PASS
Reset sequence was executed successfully. (However, this test result does 
not indicate whether the firmware diagnostic tests passed.)
1. Enter display errors to check the error log for any failed diagnostic 
firmware tests. (This is indicated by an entry of Error Type #1 for this 
circuit pack’s location.)
2. Enter display alarms to check the alarm log for any ON-BOARD 
MAJOR alarms.
0
NO 
BOARD
The system software found no board.
1. Reset the board.
2. Remotely retry the command.