Avaya 03-300430 User Manual

Page of 2574
DS1C-BD
Issue 1 June 2005
1107
 
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABRT
The timer could not be set before sending the downlink message 
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2316
ABRT
Fiber link is not administered. Administer the DS1 converter fiber link via 
add fiber-link.
2321
ABRT
DS1 converter circuit pack is not busied out. Busyout the DS1 converter 
circuit pack via busyout board.
2332
ABRT
With this system configuration (unduplicated PNC), the test was aborted 
because it cannot be run at the far end when there is only one DS1-FAC 
available. (The link would be lost, and no test results would be seen at the 
media server). Run the test at the other end of the DS1C complex.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
Table 376: Test #789 Far-End FOT (Lightwave Transceiver) Loop-Back Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3