Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1116 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its recommended procedures.
b. There are two possible alarm levels for this error: Major alarm and Minor alarm. A Major
alarm is raised if the total number of DTMR ports currently in service is less than or equal to
1/2 of the administered threshold number. Otherwise, a Minor alarm is raised. In either
case, run the short test sequence against the DTMR port and follow the error code
procedures for the individual tests.
1/2 of the administered threshold number. Otherwise, a Minor alarm is raised. In either
case, run the short test sequence against the DTMR port and follow the error code
procedures for the individual tests.
The threshold number of DTMR ports for service is administered using change
system-parameters maintenance.
system-parameters maintenance.
c. Error Type 257 The DTMR port lost its translation. Testing the DTMR port is sufficient to
reload its translation. If testing the DTMR port does not clear the error, then the IPSI or Tone
Detector circuit pack containing the defective DTMR port should be replaced.
Detector circuit pack containing the defective DTMR port should be replaced.
d. Error Type 513: This error indicates the DTMR port is having problems detecting
touch-tone digits. If this error is being constantly logged, then the IPSI or Tone Detector
circuit pack containing the defective DTMR port should be replaced.
circuit pack containing the defective DTMR port should be replaced.
e. Error Type 130: This error type indicates that the circuit pack has been removed or has
been insane for at least 11 minutes. To clear the error, reinsert or replace the circuit pack.
Table 379: Dual-Tone Multifrequency Receiver Port (TTR) Error Log Entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
)
0
Any
Any
Any
test port location sh r 1
)
17664
Tone Detector
Audit/ Update test
(#43)
MAJ
MIN
ON
test port location r 2
18
0
busyout port
location
WRN
ON
release port location
130 (
)
None
WRN
ON
test port location sh r 2
257 (
17666
Tone Detector
Audit/ Update test
(#43)
MAJ
MIN
ON
test port location r 3
513 (
) Any
Tone Detection
Verification test
(#42)
MAJ
MIN
ON
test port location r 3