Communication Manager Maintenance-Object Repair Procedures
1118 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1003
ABRT
The system could not allocate a Tone Generator for the test connection. 
This may be caused by a heavy load on the system or by a faulted 
Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the PN 
where the test aborted. If so, see the recommended procedures for 
2. If a new Tone-Clock has been inserted, allow about 1 minute for 
maintenance to run on the newly inserted circuit pack.
3. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test
1. Retry the command at 1-minute intervals up to 5 times.
2006
ABRT
DTMF detection failed. Make sure that the companding mode administered 
for the system matches that of the Tone Detector: mu-law for TN748, A-law 
for TN420.
1-3
FAIL
DTMF digits were not correctly detected.
1. Run the short test sequence: test port location sh r 1.
2. If the problem persists, the system is still operating properly but 
system capacity will be reduced. In order to restore the system 
performance to normal, replace the Tone Detector or IPSI circuit pack 
containing the defective DTMR port.
PASS
The DTMR port is able to detect every touch-tone digit.
Table 380: Test #42 Tone Detection Verification Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2