Communication Manager Maintenance-Object Repair Procedures
1128 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 
5 times.
1004
ABRT
The port was seized by a valid call during the test.
1. Use display port location to determine the station extension or 
attendant number of the port.
2. Use status station or status attendant to determine the 
service state of the port.
3. If the service state indicates that the port is in use, then the port is 
unavailable for certain tests. Wait until the port is idle before retesting. 
Attendants are always in use (off-hook) if the handset is plugged in and 
the port is not busied out.
1020
ABRT
Test disabled by background testing. Use status station to determine 
when the station is available for testing.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
1
2
FAIL
The Network Processing Element (NPE) of the tested port is transmitting in 
error. This causes noisy and unreliable connections.
Error code 1 = Crosstalk test failed on the primary channel.
Error code 2 = Crosstalk test failed on the secondary channel.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
1. To ensure that this is not an intermittent problem, repeat this test up to 
10 times.
2. If complaints persist, examine the station, connections, and wiring.
Table 383: Test #9 Digital Line NPE Crosstalk Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2