Communication Manager Maintenance-Object Repair Procedures
1132 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Station Lamp Updates Test (#16)
This test lights every lamp on the terminal as specified. The lamp updates will run only if the 
station is in service. The status of the station is checked and the lamp updates are blocked from 
taking place if the station is not in the in-service state. This test does not affect the status of the 
Message Waiting lamp.
Table 385: Test #16 DIG-LINE Station Lamp Updates Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1
ABRT
System technician may have busied out the port.
1. Look for Error Type 18 (port busied out) for this port. If this error type 
is present, then release the port (release station extension
and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
3
ABRT
Station may be in ready-for-service or out-of-service state.
1. Use status station to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port is 
busy with a valid call.
1. Use display port location to determine the station extension or 
attendant number of the port. 
2. Use status station or status attendant to determine the 
service state of the port. If the port is in use, wait until it is idle before 
retesting. Attendants are always in use (off-hook) if the handset is 
plugged in and the port is not busied out.
3. Retry the command at 1-minute intervals up to 5 times.
 1 of 2