EMG-XFER (Emergency Transfer)
Issue 1 June 2005
1135
Notes:
a. Error Type 1 indicates that the Emergency Transfer switch located on the Processor circuit
pack is set to the manual ON position (up). When the Emergency Transfer switch is in this
position it generates a Major alarm.
position it generates a Major alarm.
b. Error Type 257 indicates that the Emergency Transfer switch located on the Processor
circuit pack is set to the manual OFF position (down). When the Emergency Transfer switch
is in this position it generates a Warning alarm.
is in this position it generates a Warning alarm.
System Technician-Demanded Tests: Descriptions and Error
Codes
Codes
Investigate tests in the order presented. By clearing error codes associated with the Cabinet
Query Test, you may also clear errors generated from other tests in the testing sequence.
Query Test, you may also clear errors generated from other tests in the testing sequence.
Single Carrier System
Notes:
a. See
on page 758 for a description of this test.
b. See
on page 1246 for a description of this
test.
c. See
on page 1942 for a description of this test.
Table 387: Emergency Transfer System Technician-Demanded Tests
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Cabinet Query Test (#122) (
X
X
ND
Emergency Transfer Query Test (#124)
X
X
ND
External Alarm Lead Query Test (#120) (
)
X
X
ND
Analog Ring Generator Initialization Test
(#117) (
)
X
X
ND
Analog Ring Generator Query Test (#118) (
)
X
X
ND