Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1144 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. Error 8801: the PN is unable to send up-link control messages, and the control channel of 
the PN’s TDM bus is swapped as part of the recovery procedure.
c. Error 8803: the PN is unable to send up-link control messages and the PN’s Tone-Clock is 
swapped as part of the recovery procedure.
d. Error 9901: the PN is unable to send up-link control messages, but recovers after the 
control channels of the PN’s TDM bus are swapped.
e. Error 9902: the PN is unable to send up-link control messages, but recovers after the PN’s 
active Tone-Clock is swapped.
f. Error 9903: the PN is unable to send up-link control messages, but recovers after a PNC 
interchange has taken place.
g. Error 9904: the PN is unable to send up-link control messages, but recovers after a PN 
WARM reset.
h. Error 9905: the PN is unable to send up-link control messages, but recovers after a PN 
COLD reset.
Table 393: EPN-SNTY Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0 (
)
0
Any
None
8801 (
) Any
None
8803 (
Any
None
9901 (
) Any
None
9902 (
) Any
None
9903 (
)
Any
None
9904 (
) Any
None
9905 (
) Any
None