Avaya 03-300430 User Manual

Page of 2574
ERR-LOG (Error Log)
Issue 1 June 2005
1145
 
ERR-LOG (Error Log)
S8700 | 8710
 / 
S8500
The ERR-LOG MO is responsible for the sanity of the Alarm Log, the Hardware Error Log, and 
the Software Error Log. If an inconsistency is detected in any one of these logs, every log will be 
re-initialized and a hardware error will be logged against ERR-LOG indicating the time of 
inconsistency. There are no tests and no alarms for the Error Log MO. This MO exists solely for 
the purpose of allowing errors to be logged against it.
Hardware Error Log Entries
Notes:
a. Error Type 510: An inconsistency was detected in either the Alarm Log, the Hardware Error 
Log, or the Software Error Log. The system attempts to recover the logs but, depending on 
the extent of the corruption, some or all entries in the logs may be lost. Any alarms that were 
active at the time of this error have been cleared. There is no associated test for this error.
The Aux Data value indicates when the inconsistency was found:
MO Name in Alarm Log Alarm Level
Initial Command to Run
Full Name of MO
ERR-LOG
none
none
Error Log
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
) See Note
none
none
none
none
0
During a periodic audit of the Error Log
1
After an extended reboot
2
After a reboot
3
After a Reset System 3 (Cold_1)
4
After a Level-3 System Reset (Cold_1)
4
After a Reset System 2 (Cold_2)
8
After a Level-2 System Reset (Cold_2)
16
After a Level-1 System Reset (Warm Start)
100
After an internal software audit
2500
After a single-process (MDM) restart