Link Integrity Inquiry Test (#1282)
This nondestructive test queries the C-LAN Ethernet port’s physical connections.
1007
FAIL
Ping to the destination failed due to the destination down.
1. Verify that at least one destination reachable through this port is up. 
Ping this destination (ping ip-address xxx.xxx.xxx.xxx).
2. If the ping to any destination is successful through this port, the link is 
up, although some destinations are unreachable. Ignore the failure.
3. If ping to every destination fails, test this port (test port location 
short), and follow the repair procedures for Session Status test 
(#1286) failures.
PASS
TCP/IP Ping test (#1281) is successful.
Table 398: Test #1281 TCP/IP Ping Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3
If . . .
Then the test . . .
C-LAN connection is present Passes
C-LAN connection is absent
Fails
There is no response
Aborts
Table 399: Test #1282 Link Integrity Inquiry Test 
Error 
Code
Test 
Result
Description / Recommendation
1124
ABRT
Ethernet link is not enabled.
1. Verify that the Ethernet link is enabled (status port location
status link n, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.