Avaya 03-300430 User Manual

Page of 2574
ETH-PT (Control LAN Ethernet)
Issue 1 June 2005
1163
 
2100
ABRT
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1
FAIL
System software indicates at least one Ethernet link session is down 
(SOME UP).
1. Isolate downed sessions (status port location or status 
link n).
2. Follow actions based on session information.
2
FAIL
System software indicates every Ethernet session is down (ALL DOWN).
1. Test the port (test port location) to verify the Ethernet Local 
Looparound test (#1278) result.
2. If test passes, wait for system software to indicate ALL UP.
If not, check the destination and other components in the path.
3. If the destination and other components in the path are in service, 
take action based on session information.
PASS
Every session is up.
Table 400: Test #1286 Session Status Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2