1170 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
System Technician-Demanded Tests:
Descriptions and Error Codes
Descriptions and Error Codes
Investigate tests in the order presented.
Tone Detection Verification Test (#42)
This test checks out a single ETR port’s touch-tone receiver mode, MFC tone-detection/
generation mode, and general-purpose tone-detection mode. During the test sequence, these
modes are tested in the following order:
generation mode, and general-purpose tone-detection mode. During the test sequence, these
modes are tested in the following order:
1. Touch-tone receivers
2. General-purpose, call-progress, and maintenance tones
3. MFC tones
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Tone Detection Verification test (#42)
X
X
ND
Tone Detection Audit/Update test (#43)
X
X
ND
Table 403: Test #42 Tone Detection Verification Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
none
ABRT
The system was not able to allocate every resource needed for this
test, or there was an internal system error.
test, or there was an internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1
ABRT
The system could not allocate every resource needed to test the tones.
1. Retry the command at 1-minute intervals up to 5 times.
1001
ABRT
The system was unable to put the ETR-PT in the appropriate mode to
test it.
test it.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 3