1172 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
102
FAIL
2225-Hz Modem Answer Tone was not detected correctly. This 
impacts call-classification operation.
1. Run the short test sequence via test port location sh r 
1.
2. If the problem persists, the system can still operate properly but 
capacity is reduced. In order to restore performance to normal, 
replace the circuit pack containing the defective port. Follow the 
procedures described in 
page 2327 for replacing a Tone-Clock circuit pack.
130
FAIL
Forward or Backward MFC signals were not correctly generated or 
detected. This will impact MFC calls.
1. Run the short test sequence via test port location sh r 
1.
2. If the problem persists, the system can still operate properly but 
capacity will be reduced. In order to restore performance to 
normal, replace the TN2182/TN2312AP circuit pack containing the 
defective ETR-PT. Follow the procedures described in 
on page 2327 for replacing a Tone-Clock 
circuit pack.
 
PASS
Tone detection verification is successful. The ETR port is able to detect/
generate every necessary tone.
Table 403: Test #42 Tone Detection Verification Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3