Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1190 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Replacing an EI Circuit Pack— Duplicated PNC
On a system with duplicated PNC, synchronization may be provided over a combination of 
active and standby components. This condition is indicated by an OFF-BOARD WARNING 
alarm against TDM-CLK with Error Type 2305. Repairs to standby PNC in this state may disrupt 
service. Otherwise, if the active PNC is functional, replacement of a standby component will not 
disrupt service.
Step Action
Explanation / Caution 
1.
Enter busyout board 
location.
location = cabinet-carrier-slot location of the 
circuit pack to be replaced.
2.
Replace the circuit pack.
3.
Wait for the circuit pack to reset.
Red and green LEDs light and then go out.
If the red LED remains lit, see the previous note 
under 
4.
Enter release board 
location.
CAUTION: Do not busyout any EI circuit packs 
after this point.
5.
Enter test alarms long 
clear for category exp-intf.
6.
Wait 5 minutes for SNI-BD, 
FIBER-LK, and DS1C-BD alarms 
to clear, or enter clear 
firmware-counters a-pnc.
Step
Action
Explanation / Caution
1.
Enter status pnc.
Verify that the component to be replaced 
is on the standby PNC.
2.
Enter busyout pnc.
3.
Enter busyout board location.
location represents the 
cabinet-carrier-slot location of the circuit 
pack to be replaced.
4.
Replace the circuit pack.
5.
Enter release board location.
CAUTION: Do not busyout any EI circuit 
packs after this point.
6.
Enter test alarms long clear for 
category exp-intf.
 1 of 2